AJPH
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


American Journal of Public Health, Vol. 88, Issue 12 1781-1786, Copyright © 1998 by American Public Health Association

This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Purchase Article
Right arrow View Shopping Cart
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Levy, J I
Right arrow Articles by Spengler, J D
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Levy, J I
Right arrow Articles by Spengler, J D
Determinants of nitrogen dioxide concentrations in indoor ice skating rinks.

J I Levy, K Lee, Y Yanagisawa, P Hutchinson and J D Spengler

Department of Environmental Health, Harvard School of Public Health, Boston, Mass. 02115, USA.

OBJECTIVES: The combination of poor ventilation and fuel-powered ice resurfacers has resulted in elevated nitrogen dioxide (NO2) concentrations in many indoor ice skating rinks. This study examined the factors influencing concentrations and the effects of various engineering controls in ice rinks with different resurfacer fuels. METHODS: Indoor NO2 concentrations were measured in 19 enclosed ice skating rinks over 3 winters by means of passive samplers, with 1-week average measurements during the first winter pilot study and single-day working-hour measurements in the final 2 winters. Personal exposures to drivers also were assessed during the last winter. RESULTS: Rinks in which propane-fueled resurfacers were used had a daily mean indoor NO2 concentration of 206 ppb, compared with 132 ppb for gasoline-fueled and 37 ppb for electric-powered resurfacers. Engineering controls, such as increased ventilation and resurfacer tuning, reduced NO2 concentrations by 65% on average, but outcomes varied widely, and concentrations increased in subsequent months. CONCLUSIONS: Electric ice resurfacers, increased ventilation, or emission control systems are recommended to protect the health of workers and patrons, with surveillance programs proposed to track implementation and maintain an observer effect.




This article has been cited by other articles:


Home page
Occup. Environ. Med.Home page
T W Pelham, L E Holt, and M A Moss
Exposure to carbon monoxide and nitrogen dioxide in enclosed ice arenas
Occup. Environ. Med., April 1, 2002; 59(4): 224 - 233.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1998 by the American Public Health Association